What R-value does blown-in insulation give per inch?
The U.S. Department of Energy lists loose-fill cellulose at about R-3.2 to R-3.8 per inch and loose-fill fiberglass at R-2.2 to R-2.7 per inch. Divide your target R-value (R-30 to R-60 depending on climate zone) by the material's per-inch figure to estimate the depth it needs - cellulose reaches a given target in noticeably less depth than fiberglass.

Why doesn't R-value scale evenly with thickness?
Because settled density rises as depth increases, the R-value of loose-fill does not change proportionately with thickness (U.S. DOE, Energy Saver). That is also why installers blow cellulose in thicker than the final target: it settles about 13% after installation, so 17 inches of settled thickness typically means installing roughly 20 inches (GreenBuildingAdvisor). Fiberglass settles far less, so its installed depth stays closer to its rated depth. Measure the depth you actually have, not the depth that was installed years ago.
Sources
3 cited- Loose-fill fiberglass and cellulose R-value per inch: U.S. Department of Energy, Building America Solution Center, Loose-Fill Insulation (checked 2026-08-19).
- R-value-vs-thickness behavior: U.S. Department of Energy, Energy Saver, Types of Insulation (checked 2026-08-19).
- Cellulose settling (~13%) and installed-vs-settled depth: GreenBuildingAdvisor, Blown-in cellulose (settling) (checked 2026-08-19).